Local cover image
Local cover image
Image from Google Jackets

Measurement of High Voltage Lines in Real Time

By: Publication details: Telangana IUP Publications 2023Edition: Vol, 16(1), JanDescription: 37-57pSubject(s): In: IUP journal of electrical and electronics engineeringSummary: Investigation consists of taking data from insulator of 220k v voltage lines located in the coastal areas of peru. line 2212 from huacho to Zapallal was chosen,and the data consists of audios and images taken at night when there is low temperature and high relative humidity, with the objective of identifying the characteristics that show the occurrence of effluvia, which are atmospheric discharges due to the voltage of the line and the environmental conditions- a phenomenon known as the corona effect; Data ware taken during the months of October 2020 and Jun-July 2022 that included more than 20 thousand archives of video, audio, and data(collected in csv type files), allowing to determine that the corona effect does not manifest it self during the moments of lowest temperature.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology Archieval Section Not for loan 2023-1044
Total holds: 0

Investigation consists of taking data from insulator of 220k v voltage lines located in the coastal areas of peru. line 2212 from huacho to Zapallal was chosen,and the data consists of audios and images taken at night when there is low temperature and high relative humidity, with the objective of identifying the characteristics that show the occurrence of effluvia, which are atmospheric discharges due to the voltage of the line and the environmental conditions- a phenomenon known as the corona effect; Data ware taken during the months of October 2020 and Jun-July 2022 that included more than 20 thousand archives of video, audio, and data(collected in csv type files), allowing to determine that the corona effect does not manifest it self during the moments of lowest temperature.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.