Experimental heat transfer rate on vertical pipes of a simple water harvester

By: Contributor(s): Publication details: Prayagraj Pushpa Publishing House 2023Edition: Vol.33, JunDescription: 41-50pSubject(s): Online resources: In: JP journal of heat and mass transferSummary: One of the tools that can be used to produce clean water is a water harvester. However, this tool is still very low in water production, so it needs to be investigated to increase its water production. This study examines the heat transfer rate from the air to the outer walls of pipes of an evaporator used in the simple air-water harvester. The pipe lengths that varied were 20cm, 40cm and 60cm which were arranged vertically with 138 pipes. The corresponding heat transfer areas were 0.2008m2, 0.3534m2 and 0.5039m2. The results showed that the highest freshwater mass was 308g/7 hours found at the heat transfer area of 0.3534m2, while the highest total heat transfer rate obtained was 59.6W. This study could be used as a reference to design an evaporator of a simple air-water harvester.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology Archieval Section Not for loan 2023-1614
Total holds: 0

One of the tools that can be used to produce clean water is a water harvester. However, this tool is still very low in water production, so it needs to be investigated to increase its water production. This study examines the heat transfer rate from the air to the outer walls of pipes of an evaporator used in the simple air-water harvester. The pipe lengths that varied were 20cm, 40cm and 60cm which were arranged vertically with 138 pipes. The corresponding heat transfer areas were 0.2008m2, 0.3534m2 and 0.5039m2. The results showed that the highest freshwater mass was 308g/7 hours found at the heat transfer area of 0.3534m2, while the highest total heat transfer rate obtained was 59.6W. This study could be used as a reference to design an evaporator of a simple air-water harvester.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.