Behavior of the column stubs of telecommunication towers strengthened with different types of FRP fabrics

By: Contributor(s): Publication details: Mumbai Springer 2024Edition: Vol.105(1), MarDescription: 25-36pSubject(s): Online resources: In: Journal of the institution of engineers (India): Series ASummary: The research investigated the behavior of reinforced concrete column stubs of telecommunication towers, which are strengthened with FRP fabrics. Six RC full-scale telecom column stubs with a square cross section and anchor bolts in the center were tested experimentally under concentric load. The experimental study is implemented to demonstrate the influence of confining FRP composite on the performance of telecom column stubs under axial loading. Parameters investigated by specimens were the influence of FRP number of layers, FRP type and FRP orientation on the axial load capacity, stiffness, ductility, and energy absorption of full-sized telecom stubs. The experimental results indicated significant enhancement in capacity and axial deformation of telecom column stubs fully wrapped with double unidirectional CFRP sheet when compared with double-wrapped heavy bidirectional GFRP light or heavy sheet. Examined specimens showed a noticeable increase in terms of strain values compared to unconfined specimens when the number of plies increased. Edges are circulated as FRP sheet ruptured due to the accumulation of confinement effect in specimens' corners. Ductility and energy absorption of column stubs wrapped with GFRP sheets were lesser than CFRP with the same plies number, even though GFRP was heavy-woven mesh sheets, not unidirectional light sheets. CFRP ductility index reached more than double the control by about 207%. It is noticed that load capacity calculations of telecom stub columns based on ECP 203–2020 and ECP 208–2015 calculations were more conservative than ACI 318–19 and ACI 440.2R-17 calculations when compared to experimental test results.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG) Archieval Section Not for loan 2025-0025
Total holds: 0

The research investigated the behavior of reinforced concrete column stubs of telecommunication towers, which are strengthened with FRP fabrics. Six RC full-scale telecom column stubs with a square cross section and anchor bolts in the center were tested experimentally under concentric load. The experimental study is implemented to demonstrate the influence of confining FRP composite on the performance of telecom column stubs under axial loading. Parameters investigated by specimens were the influence of FRP number of layers, FRP type and FRP orientation on the axial load capacity, stiffness, ductility, and energy absorption of full-sized telecom stubs. The experimental results indicated significant enhancement in capacity and axial deformation of telecom column stubs fully wrapped with double unidirectional CFRP sheet when compared with double-wrapped heavy bidirectional GFRP light or heavy sheet. Examined specimens showed a noticeable increase in terms of strain values compared to unconfined specimens when the number of plies increased. Edges are circulated as FRP sheet ruptured due to the accumulation of confinement effect in specimens' corners. Ductility and energy absorption of column stubs wrapped with GFRP sheets were lesser than CFRP with the same plies number, even though GFRP was heavy-woven mesh sheets, not unidirectional light sheets. CFRP ductility index reached more than double the control by about 207%. It is noticed that load capacity calculations of telecom stub columns based on ECP 203–2020 and ECP 208–2015 calculations were more conservative than ACI 318–19 and ACI 440.2R-17 calculations when compared to experimental test results.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.