Numerical modeling of the quasi-static and dynamic response of an earthen dam: case of the Ourkiss dam

By: Contributor(s): Publication details: Mumbai Springer 2025Edition: Vol.55(2), AprDescription: 766-780pSubject(s): Online resources: In: Indian geotechnical journalSummary: The construction of earth dams on active faults presents a risk of instability. The Ourkiss dam, built 14 km south of the town of Ain Fakroun, is a heterogeneous type of dam made of clay and alluvial materials, with a watertight geo-membrane lining on the upstream face of the dam and on the dam flanks. Due to its location close to active faults, the dam could be damaged by instability in the event of a very strong earthquake. For this reason, in this article a comparison between two study approaches is made: one is quasi-static based on a failure analysis due to the effect of normal and reverse fault propagation. Different angles of inclination are applied by sliding through the Ourkiss dam at the end of construction and in the filled state. The other approach is based on the dynamic effect of the 2003 Boumerdes earthquake (magnitude 6.9 on the Richter scale), modeled with a sinusoidal propagation velocity applied to the model base in the horizontal direction. The results obtained for both approaches are presented in terms of shear deformations developed at the dam foundation and dike. They show that the deformation values found by the quasi-static method are greater than those found by the dynamic method.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG) Archieval Section Not for loan 2025-1573
Total holds: 0

The construction of earth dams on active faults presents a risk of instability. The Ourkiss dam, built 14 km south of the town of Ain Fakroun, is a heterogeneous type of dam made of clay and alluvial materials, with a watertight geo-membrane lining on the upstream face of the dam and on the dam flanks. Due to its location close to active faults, the dam could be damaged by instability in the event of a very strong earthquake. For this reason, in this article a comparison between two study approaches is made: one is quasi-static based on a failure analysis due to the effect of normal and reverse fault propagation. Different angles of inclination are applied by sliding through the Ourkiss dam at the end of construction and in the filled state. The other approach is based on the dynamic effect of the 2003 Boumerdes earthquake (magnitude 6.9 on the Richter scale), modeled with a sinusoidal propagation velocity applied to the model base in the horizontal direction. The results obtained for both approaches are presented in terms of shear deformations developed at the dam foundation and dike. They show that the deformation values found by the quasi-static method are greater than those found by the dynamic method.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.