Enantioselective analysis of guaienesin in bulk and pharmaceutival dosage forms by chiral reverse phase HPLC-PDA method

By: Contributor(s): Publication details: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (02) FebruaryDescription: 36-43Subject(s): In: Indian drugsSummary: A novel, accurate and precise chiral reverse-phase high pressure liquid chromatographic method was developed for enantioselective analysis of guaifenesin (GFN) in bulk and tablet dosage forms. Chiral separation was achieved on phenomenex Lux Cellulose-4 column (250×4.6mm, 5μ) using 0.02% formic acid: acetonitrile (90:10 V/V) as the mobile phase at a flow rate of 1mL/min at 230nm. The retention times of GFN enantiomers A and B was 15 and 16 minutes, respectively, with good peak resolutions and showing good linearity in the concentration range of 10-50 μg/mL (R2 > 0.999). The developed method was validated as per the International Conference on Harmonization guidelines and the results were well within the acceptable limits. The percentage assay in tablet dosage form was found to be 98.8 and 98.2 respectively, for enantiomers A and B and was with in the compendial specifications, demonstrating the suitability of developed method for enantioselective analysis of guaifenesin racemic mixture.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2018015
Total holds: 0

A novel, accurate and precise chiral reverse-phase high pressure liquid chromatographic method was developed for enantioselective analysis of guaifenesin (GFN) in bulk and tablet dosage forms. Chiral separation was achieved on phenomenex Lux Cellulose-4 column (250×4.6mm, 5μ) using 0.02% formic acid: acetonitrile (90:10 V/V) as the mobile phase at a flow rate of 1mL/min at 230nm. The retention times of GFN enantiomers A and B was 15 and 16 minutes, respectively, with good peak resolutions and showing good linearity in the concentration range of 10-50 μg/mL (R2 > 0.999). The developed method was validated as per the International Conference on Harmonization guidelines and the results were well within the acceptable limits. The percentage assay in tablet dosage form was found to be 98.8 and 98.2 respectively, for enantiomers A and B and was with in the compendial specifications, demonstrating the suitability of developed method for enantioselective analysis of guaifenesin racemic mixture.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.