Image from Google Jackets

Development and validation of RP-HPLC method for the determination of alvimopan in rat plasma

By: Contributor(s): Publication details: M. P. Innovare Academic Sciences Pvt Ltd 2018Edition: Vol. 10(10), July-AugustDescription: 124-129Subject(s): Online resources: In: International journal of pharmacy and pharmaceutical scienceSummary: Objective: The present investigation demonstrates a simple, sensitive and accurate high pressure liquid chromatographic (HPLC) method for the determination of alvimopan (AMP) in rat plasma. Methods: The chromatographic separation was achieved within 10 min by using acetonitrile: potassium dihydrogen phosphate buffer pH 3.0 adjusted with orthophosphoric acid (50:50) as mobile phase on Altima Grace Smart C-18 column (5μ; 250 × 4.6 mm) at a flow rate of 1.0 ml/min with injection volume 50 μl. The drug was extracted from plasma by liquid-liquid extraction using a mixture of methanol: acetonitrile (50:50) as a solvent. The retention times of drug and internal standard were found to be 5.17 and 6.74 min, respectively. This method was validated as per the United States Food and Drug Administration (US-FDA) guidelines. Results: The results of the validation parameters were found to be within the acceptance limits. The method was linear in the concentration range from 5-1000 ng/ml (r2= 0.9998), and the extraction recovery was found to be 78.71±3.86% for AMP. The lower limit of quantification was found to be 5ng/ml, and the stability of recovered samples at different conditions was found to be more than 95%. Conclusion: The developed method possess good selectivity, specificity, there was no interference found in the plasma blanks at retention times of AMP and Internal Standard (IS). We found a good correlation between the peak area and con.....
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2018430
Total holds: 0

Objective: The present investigation demonstrates a simple, sensitive and accurate high pressure liquid chromatographic (HPLC) method for the determination of alvimopan (AMP) in rat plasma. Methods: The chromatographic separation was achieved within 10 min by using acetonitrile: potassium dihydrogen phosphate buffer pH 3.0 adjusted with orthophosphoric acid (50:50) as mobile phase on Altima Grace Smart C-18 column (5μ; 250 × 4.6 mm) at a flow rate of 1.0 ml/min with injection volume 50 μl. The drug was extracted from plasma by liquid-liquid extraction using a mixture of methanol: acetonitrile (50:50) as a solvent. The retention times of drug and internal standard were found to be 5.17 and 6.74 min, respectively. This method was validated as per the United States Food and Drug Administration (US-FDA) guidelines. Results: The results of the validation parameters were found to be within the acceptance limits. The method was linear in the concentration range from 5-1000 ng/ml (r2= 0.9998), and the extraction recovery was found to be 78.71±3.86% for AMP. The lower limit of quantification was found to be 5ng/ml, and the stability of recovered samples at different conditions was found to be more than 95%. Conclusion: The developed method possess good selectivity, specificity, there was no interference found in the plasma blanks at retention times of AMP and Internal Standard (IS). We found a good correlation between the peak area and con.....

There are no comments on this title.

to post a comment.
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.