Development and validation of RP HPLC method for the estimation of sofosbuvir in bulk, tablet and industrial waste water

By: Contributor(s): Publication details: Mumbai Indian Drug Manufacture's Association - IDMA 2019Edition: Vol. 56 (06)Description: 59-66Subject(s): Online resources: In: Indian drugsSummary: The study was aimed at development and validation of RP-HPLC method for estimation of sofosbuvir in bulk, pharmaceutical dosage form and pharmaceutical industrial waste. The chromatographic separation was performed on Agilent Syncronis C 18 (100 mm × 4.6 mm, 5μm) column, with a mobile phase comprising of a mixture of methanol: acetonitrile: water (45:30:25 v/v/V). The flow rate was 1.0 mL/min with detection at 260 nm. Retention time of sofosbuvir was found to be 2.040 min. As per ICH guidelines, the method was validated for linearity, accuracy, limit of detection, limit of quantitation, precision, robustness and system suitability. Linearity was found to be in the range of 4-24 μg/mL with regression equation y = 675284.x + 49120 and correlation coefficient 0.999. The low % RSD values indicate the method to be accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.046 and 0.1400 μg/mL, respectively. The % recovery of tablets was found to be in the range of 99.9– 101.3%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for estimation of sofosbuvir in bulk, tablet and applicable for analyses of in pharmaceutical industrial waste.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2019731
Total holds: 0

The study was aimed at development and validation of RP-HPLC method for estimation of sofosbuvir in bulk, pharmaceutical dosage form and pharmaceutical industrial waste. The chromatographic separation was performed on Agilent Syncronis C 18 (100 mm × 4.6 mm, 5μm) column, with a mobile phase comprising of a mixture of methanol: acetonitrile: water (45:30:25 v/v/V). The flow rate was 1.0 mL/min with detection at 260 nm. Retention time of sofosbuvir was found to be 2.040 min. As per ICH guidelines, the method was validated for linearity, accuracy, limit of detection, limit of quantitation, precision, robustness and system suitability. Linearity was found to be in the range of 4-24 μg/mL with regression equation y = 675284.x + 49120 and correlation coefficient 0.999. The low % RSD values indicate the method to be accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.046 and 0.1400 μg/mL, respectively. The % recovery of tablets was found to be in the range of 99.9– 101.3%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for estimation of sofosbuvir in bulk, tablet and applicable for analyses of in pharmaceutical industrial waste.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.