Local cover image
Local cover image
Image from Google Jackets

Development of validated stability indicating method by RP-HPLC for simultaneous estimation of meropenem and vaborbactam in bulk an pharmaceutical formulation

By: Contributor(s): Publication details: Bhopal Innovare Academic Sciences Pvt Ltd 2019Edition: Vol. 11 (07)Description: 102-108pSubject(s): Online resources: In: International journal of pharmacy and pharmaceutical scienceSummary: Objective: To develop a simple, rapid, precise and reproducible liquid chromatographic method for the estimation meropenem (MEP) and vaborbactam (VAB) in bulk and pharmaceutical formulation and study of the stability of the drugs in different stressed conditions. Methods: The chromatographic separation was achieved on a Kromasil C18 column (250 × 4.6 mm) using a mobile phase composition of acetonitrile and 10 mmol phosphate buffer (pH 3.50) in a ratio 30:70 v/v, pumped at a flow rate of 1.0 ml/min with UV detection set at 260 nm. Results: Symmetrical and sharp peaks of MEP and VAB were obtained at retention times of 2.29 and 3.10 min, respectively. The chromatographic method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 25–150 μg/ml for MEP and VAB. Stability tests done through the exposure of the analytes solution for different stress conditions and the obtained results indicate no interference of degradants with HPLC method. Conclusion: The proposed method has been found to be selective, precise, linear, accurate, and sensitive. The method can be successfully applied to the assay determination of bulk drugs and combined dosage forms for routine analysis. Keywords: Meropenem, Vaborbactam, Method development, RP-HPLC
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2020176
Total holds: 0

Objective: To develop a simple, rapid, precise and reproducible liquid chromatographic method for the estimation meropenem (MEP) and vaborbactam (VAB) in bulk and pharmaceutical formulation and study of the stability of the drugs in different stressed conditions.

Methods: The chromatographic separation was achieved on a Kromasil C18 column (250 × 4.6 mm) using a mobile phase composition of acetonitrile and 10 mmol phosphate buffer (pH 3.50) in a ratio 30:70 v/v, pumped at a flow rate of 1.0 ml/min with UV detection set at 260 nm.

Results: Symmetrical and sharp peaks of MEP and VAB were obtained at retention times of 2.29 and 3.10 min, respectively. The chromatographic method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 25–150 μg/ml for MEP and VAB. Stability tests done through the exposure of the analytes solution for different stress conditions and the obtained results indicate no interference of degradants with HPLC method.

Conclusion: The proposed method has been found to be selective, precise, linear, accurate, and sensitive. The method can be successfully applied to the assay determination of bulk drugs and combined dosage forms for routine analysis.
Keywords: Meropenem, Vaborbactam, Method development, RP-HPLC

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.