Local cover image
Local cover image
Image from Google Jackets

Modal Identification of Practical Engineering Structures using Second-Order Blind Identification

By: Contributor(s): Publication details: New York Springer 2021Edition: Vol.102(2), JuneDescription: 499-512pSubject(s): Online resources: In: Journal of the institution of engineers (India): Series ASummary: It is highly desirable to have a reliable modal parameter estimation technique with output-only measurements, especially for tall structures subjected to ambient wind loads. A modal identification technique called second-order blind identification (SOBI) is discussed in this paper to estimate the modal parameters of tall structures subjected to ambient loading. This method requires only acceleration time history data. The data are first preprocessed through cross-correlations to obtain the free response. SOBI uses these free responses to generate the mixing matrix (i.e., modal matrix) and sources, which are the modal responses of the structure. Even though SOBI has earlier been employed for modal parameter estimation, the majority of works attempt to solve small academic problems. Keeping this in view, we attempt to solve some practical engineering problems associated with tall structures. The proposed modal estimation technique is first evaluated using synthetic data of a 76-story tall benchmark building with varying levels of noise and later validated with the experimental data of the 610 m tall Guangzhou New TV Tower (GNTVT). Investigations carried out in this paper, using numerical and experimental ambient responses of tall structures, clearly indicate that the modal parameters estimated using SOBI are comparing very well with theoretical values.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG) Archieval Section Not for loan 2021-2022051
Total holds: 0

It is highly desirable to have a reliable modal parameter estimation technique with output-only measurements, especially for tall structures subjected to ambient wind loads. A modal identification technique called second-order blind identification (SOBI) is discussed in this paper to estimate the modal parameters of tall structures subjected to ambient loading. This method requires only acceleration time history data. The data are first preprocessed through cross-correlations to obtain the free response. SOBI uses these free responses to generate the mixing matrix (i.e., modal matrix) and sources, which are the modal responses of the structure. Even though SOBI has earlier been employed for modal parameter estimation, the majority of works attempt to solve small academic problems. Keeping this in view, we attempt to solve some practical engineering problems associated with tall structures. The proposed modal estimation technique is first evaluated using synthetic data of a 76-story tall benchmark building with varying levels of noise and later validated with the experimental data of the 610 m tall Guangzhou New TV Tower (GNTVT). Investigations carried out in this paper, using numerical and experimental ambient responses of tall structures, clearly indicate that the modal parameters estimated using SOBI are comparing very well with theoretical values.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.