Local cover image
Local cover image
Image from Google Jackets

Method development and validation of ursodeoxycholic acid by UV spectroscopy

By: Contributor(s): Publication details: Raipur Asian Pharma Press 2024Edition: Vol.14(3), Jul-SepDescription: 122-126pSubject(s): Online resources: In: Asian journal of pharmaceutical analysisSummary: This work presents UV spectroscopy-based UDCA development and validation. For the estimation of ursodeoxycholic, a quick, accurate, and affordable UV-spectroscopic approach has been established. Ursodeoxycholic acid was discovered to have an absorption maximum in methanol of 205nm. With a correlation coefficient of 0.983, the medication exhibits linear behaviour in the concentration ranges of 2 – 10g/ml at 205 nm. The recovery experiment, which was carried out at three levels of 80%, 100%, and 120%, was used to evaluate the method's accuracy. The percent recovery was discovered to be between 90% and 120%. Low percentages of RSD are a sign of a method's accuracy and reproducibility. The %RSD 2 shows that the procedure is accurate. Less than 2% was robust and rugged, which is in-acceptable range3.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2025-0007
Total holds: 0

This work presents UV spectroscopy-based UDCA development and validation. For the estimation of ursodeoxycholic, a quick, accurate, and affordable UV-spectroscopic approach has been established. Ursodeoxycholic acid was discovered to have an absorption maximum in methanol of 205nm. With a correlation coefficient of 0.983, the medication exhibits linear behaviour in the concentration ranges of 2 – 10g/ml at 205 nm. The recovery experiment, which was carried out at three levels of 80%, 100%, and 120%, was used to evaluate the method's accuracy. The percent recovery was discovered to be between 90% and 120%. Low percentages of RSD are a sign of a method's accuracy and reproducibility. The %RSD 2 shows that the procedure is accurate. Less than 2% was robust and rugged, which is in-acceptable range3.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.