Reverse phase high performance liquid chromatographic method for determination of regorafenib in tablet dosage form

By: Contributor(s): Publication details: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (06) JuneDescription: 63-68Subject(s): In: Indian drugsSummary: A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2018029
Total holds: 0

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.