Review on Modified Air Cooler with De-humidification (Record no. 10506)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20191210151730.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191210b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 11125
Author Vyas, Rushang
245 ## - TITLE STATEMENT
Title Review on Modified Air Cooler with De-humidification
250 ## - EDITION STATEMENT
Volume, Issue number Vol.8(1), Jan-Apr
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Noida
Name of publisher, distributor, etc. STM Journals
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 11-14p.
520 ## - SUMMARY, ETC.
Summary, etc. The desert cooler is based on working principal of direct evaporative cooling system. So, when the desert cooler is used, air is cool with high humidity or moisture content, so because of that it is used only at dry places, and it is the big limitation of the desert cooler. To remove this limitation, we modified the working and structure of the air cooler. The modified air cooler works based on indirect evaporative cooling system, because of that the air will transfer the heat with use of indirect heat transfer process. So air will not absorb the moisture content with itself and air is not humidified. And because of temperature difference, there will be de-humidification also carried out, so in last we get cooled and de-humidified air. The modified air cooler will have the same economy, because of it all people can use it easily who cannot afford air conditioning system or other cooling systems. The desert cooler supplies humidified air, so it harms the human body because it contains high moisture content, and humans at normal place cannot sustain that kind of air flow. The modified air cooler will give dehumidified and cool air so it will near to the comfort zone of human body at normal places (25°C temperature and 50–60% relative humidity), so human will feel good because of dehumidified and cool air, and they will be able to do their work effectively. It is the main purpose to modifying the air cooler.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4626
Topical term or geographic name entry element Mechanical Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 11112
Co-Author Hindocha, Hardik P.
773 0# - HOST ITEM ENTRY
International Standard Serial Number 2347-9965
Title Recent trends in mechanical engineering & technology (TMET)
Place, publisher, and date of publication Noida STM Journals
856 ## - ELECTRONIC LOCATION AND ACCESS
URL http://engineeringjournals.stmjournals.in/index.php/TMET/article/view/334
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2019-12-10 2020436 2019-12-10 2019-12-10 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha