Normal view MARC view ISBD view

Review on Modified Air Cooler with De-humidification

By: Vyas, Rushang.
Contributor(s): Hindocha, Hardik P.
Publisher: Noida STM Journals 2018Edition: Vol.8(1), Jan-Apr.Description: 11-14p.Subject(s): Mechanical EngineeringOnline resources: Click here In: Recent trends in mechanical engineering & technology (TMET)Summary: The desert cooler is based on working principal of direct evaporative cooling system. So, when the desert cooler is used, air is cool with high humidity or moisture content, so because of that it is used only at dry places, and it is the big limitation of the desert cooler. To remove this limitation, we modified the working and structure of the air cooler. The modified air cooler works based on indirect evaporative cooling system, because of that the air will transfer the heat with use of indirect heat transfer process. So air will not absorb the moisture content with itself and air is not humidified. And because of temperature difference, there will be de-humidification also carried out, so in last we get cooled and de-humidified air. The modified air cooler will have the same economy, because of it all people can use it easily who cannot afford air conditioning system or other cooling systems. The desert cooler supplies humidified air, so it harms the human body because it contains high moisture content, and humans at normal place cannot sustain that kind of air flow. The modified air cooler will give dehumidified and cool air so it will near to the comfort zone of human body at normal places (25°C temperature and 50–60% relative humidity), so human will feel good because of dehumidified and cool air, and they will be able to do their work effectively. It is the main purpose to modifying the air cooler.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2020436
Total holds: 0

The desert cooler is based on working principal of direct evaporative cooling system. So, when the desert cooler is used, air is cool with high humidity or moisture content, so because of that it is used only at dry places, and it is the big limitation of the desert cooler. To remove this limitation, we modified the working and structure of the air cooler. The modified air cooler works based on indirect evaporative cooling system, because of that the air will transfer the heat with use of indirect heat transfer process. So air will not absorb the moisture content with itself and air is not humidified. And because of temperature difference, there will be de-humidification also carried out, so in last we get cooled and de-humidified air. The modified air cooler will have the same economy, because of it all people can use it easily who cannot afford air conditioning system or other cooling systems. The desert cooler supplies humidified air, so it harms the human body because it contains high moisture content, and humans at normal place cannot sustain that kind of air flow. The modified air cooler will give dehumidified and cool air so it will near to the comfort zone of human body at normal places (25°C temperature and 50–60% relative humidity), so human will feel good because of dehumidified and cool air, and they will be able to do their work effectively. It is the main purpose to modifying the air cooler.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha