000 -LEADER |
fixed length control field |
a |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20221003101048.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
221003b xxu||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
AIKTC-KRRC |
Transcribing agency |
AIKTC-KRRC |
100 ## - MAIN ENTRY--PERSONAL NAME |
9 (RLIN) |
18198 |
Author |
Defrianto, Defrianto |
245 ## - TITLE STATEMENT |
Title |
External perspective of lung airflow model through diaphragm breathing sensor using fiber optic elastic belt |
250 ## - EDITION STATEMENT |
Volume, Issue number |
Vol.60(7), Jul |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
New Delhi |
Name of publisher, distributor, etc. |
CSIR |
Year |
2022 |
300 ## - PHYSICAL DESCRIPTION |
Pagination |
561-566p. |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Optical fiber-based detector technology is highly appreciated and developed in the field of medical physics. Through its fiber-optic wave pattern performance, this detector has great potential for monitoring difficult-to-calculate parameters such as airflow in the lungs. To realize this reality, a theoretical and experimental approach is needed in this research. The lung tissue model was formed using the Navier-Stokes equation using the finite element method by taking into account the continuity and momentum equations. While experimentally, single-mode fiber and fiber Bragg grating (FBG) was installed with a sinusoidal macro bending pattern as a strain sensor which was applied to the elastic belt and mounted on the diaphragm. The simulation model carried out depicts the velocity of air moving from the pulmonary duct to increase as it flows into smaller branches. While the experimental results show that the detected power parameter is a maximum of -0.16 dBm during inhalation and a minimum of -0.19 dBm during expiration. Due to the bending approach, the FBG sensor belt obtained the highest sensitivity at a sinusoidal bending diameter of 0.8 cm. Therefore, this is good news as a more accurate detector approach for medical purposes. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
9 (RLIN) |
4642 |
Topical term or geographic name entry element |
Humanities and Applied Sciences |
700 ## - ADDED ENTRY--PERSONAL NAME |
9 (RLIN) |
18199 |
Co-Author |
Saktioto, Toto |
773 0# - HOST ITEM ENTRY |
International Standard Serial Number |
0019-5596 |
Place, publisher, and date of publication |
New Delhi CSIR-NISCAIR |
Title |
Indian journal of pure & applied physics (IJPAP) |
856 ## - ELECTRONIC LOCATION AND ACCESS |
URL |
http://op.niscair.res.in/index.php/IJPAP/article/view/62342 |
Link text |
Click here |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
|
Koha item type |
Articles Abstract Database |