Failure investigation of transmission line towers with unfilled bolt holes in stub member (Record no. 20707)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240312103140.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240312b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 13613
Author Balagopal, R.
245 ## - TITLE STATEMENT
Title Failure investigation of transmission line towers with unfilled bolt holes in stub member
250 ## - EDITION STATEMENT
Volume, Issue number Vol.104(4), Dec
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. USA
Name of publisher, distributor, etc. Springer
Year 2023
300 ## - PHYSICAL DESCRIPTION
Pagination 867-876p.
520 ## - SUMMARY, ETC.
Summary, etc. After erection, the Transmission Line (TL) towers are left with unfilled bolt holes in stub members, which leads to failure due to buckling strength reduction. Thus, the buckling resistance of leg members is crucial in determining the overall stability of TL towers. This paper discusses forensic failure investigation of a 220 kV prototype tested TL tower with unfilled bolt holes in stub members. An analytical expression based on local and flexural buckling interaction, considering the local plate buckling near the vicinity of unfilled bolt holes on the compressive strength of stub member, has been investigated to understand the failure. Detailed component-level experimental, numerical and analytical investigations as per IS 802 (Part 1/Sec 2): 2016/ASCE 10-15: 2015 and BS 8100-3: 1999 standard design specifications have been carried out to simulate stub member failure due to the presence of unfilled bolt holes. Based on these studies, it is observed that premature failure occurred due to the local buckling of stub members with unfilled bolt holes. Hence, to prevent the failure of existing TL towers in the field, it is recommended to fill all unfilled bolt holes in stub members with dummy bolts to ensure their structural adequacy.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4642
Topical term or geographic name entry element Humanities and Applied Sciences
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 13615
Co-Author Rao, N. Prasad
773 0# - HOST ITEM ENTRY
Title Journal of the institution of engineers (India): Series A
International Standard Serial Number 2250-2149
Place, publisher, and date of publication Switzerland Springer
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40030-023-00766-1
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2024-03-12 2024-0228 2024-03-12 2024-03-12 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.