Normal view MARC view ISBD view

Failure investigation of transmission line towers with unfilled bolt holes in stub member

By: Balagopal, R.
Contributor(s): Rao, N. Prasad.
Publisher: USA Springer 2023Edition: Vol.104(4), Dec.Description: 867-876p.Subject(s): Humanities and Applied SciencesOnline resources: Click here In: Journal of the institution of engineers (India): Series ASummary: After erection, the Transmission Line (TL) towers are left with unfilled bolt holes in stub members, which leads to failure due to buckling strength reduction. Thus, the buckling resistance of leg members is crucial in determining the overall stability of TL towers. This paper discusses forensic failure investigation of a 220 kV prototype tested TL tower with unfilled bolt holes in stub members. An analytical expression based on local and flexural buckling interaction, considering the local plate buckling near the vicinity of unfilled bolt holes on the compressive strength of stub member, has been investigated to understand the failure. Detailed component-level experimental, numerical and analytical investigations as per IS 802 (Part 1/Sec 2): 2016/ASCE 10-15: 2015 and BS 8100-3: 1999 standard design specifications have been carried out to simulate stub member failure due to the presence of unfilled bolt holes. Based on these studies, it is observed that premature failure occurred due to the local buckling of stub members with unfilled bolt holes. Hence, to prevent the failure of existing TL towers in the field, it is recommended to fill all unfilled bolt holes in stub members with dummy bolts to ensure their structural adequacy.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2024-0228
Total holds: 0

After erection, the Transmission Line (TL) towers are left with unfilled bolt holes in stub members, which leads to failure due to buckling strength reduction. Thus, the buckling resistance of leg members is crucial in determining the overall stability of TL towers. This paper discusses forensic failure investigation of a 220 kV prototype tested TL tower with unfilled bolt holes in stub members. An analytical expression based on local and flexural buckling interaction, considering the local plate buckling near the vicinity of unfilled bolt holes on the compressive strength of stub member, has been investigated to understand the failure. Detailed component-level experimental, numerical and analytical investigations as per IS 802 (Part 1/Sec 2): 2016/ASCE 10-15: 2015 and BS 8100-3: 1999 standard design specifications have been carried out to simulate stub member failure due to the presence of unfilled bolt holes. Based on these studies, it is observed that premature failure occurred due to the local buckling of stub members with unfilled bolt holes. Hence, to prevent the failure of existing TL towers in the field, it is recommended to fill all unfilled bolt holes in stub members with dummy bolts to ensure their structural adequacy.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha